Home > Biofilters Bioteg Odor Control Biofilters Advantages:
·
Pre-engineered
enclosed systems for 1.8 cfm to 20,000 cfm ·
5 - 8
year biofilter media life ·
Compact Size ·
Easy to
install ·
No harmful chemicals · Minimal or no maintenance needed ·
Totally
natural process ·
Simple ·
Strong,
quality construction with corrosion proof or resistant materials ·
Vents your
collection system reducing odor and corrosion · Easy media disposal
Biofilters for Odor Control catalog
|
|

Stand Alone
·
Pre-engineered
enclosed systems for 12 cfm to 300 cfm (Custom
sizes available)
·
Up to seven
year media life
· Compact
·
Easy to
install
·
Minimized
maintenance requirements, strong,
quality HDPE construction
·
Vents
collection system reducing odor and corrosion
·
Easy media
disposal
Commonly used for filter for smell of sewer pumping stations and lift station odor control to treat odor by biofilter.
For larger capacity, use a Modular Biofilter. The HDPE construction is corrosion and maintenance free.
The conclusion from a evaluation report of a Bioteg Stand Alone Biofilter:
“... Bioteg Biofilter removes more than 98% of the odors.
The pre-packaged Bioteg Biofilter has many advantages over odor control
technologies (mist towers, packed bed scrubbers, etc.)
These advantages include relatively low capital cost, low O&M costs,
compact design, and the absence of hazardous chemicals. A practical odor
control unit, the Bioteg Biofilter should be considered for other District
projects, such as lift stations.”
Stand
Alone Odor Control Biofilters
Prevent odor complaints without adding maintenance.
Manhole Biofilter
Advantages:
Odor metabolizing bacteria self regenerates
Organic, non-toxic, biodegradable media is readily composed
Moisture aids biofilter odor treatment while moisture hinders carbon filters.
Manhole biofilter lifts in or out in 11 seconds for full access to the manhole.
Low or no maintenance
Highly effective odor removal
Earth-friendly & chemical free
Constructed from non-corroding stainless steel and HDPE
Vents treated H2S sewer gas out of sewer collection system letting fresh air in reducing corrosion and odors.
Custom built to fit your manhole dimensions
Manhole biofilter flyer
Modular odour control biofilters from 300 cfm to unlimited size by adding as many modular containers as needed. Low height for profile for minimal impact on appearance. Materials in contact with foul air: HDPE, PP, PVC, stainless steel.
Ideal for odor control for wastewater treatment plants, industrial filters.
Minimized
maintenance requirements
Simple installation, operation and media disposal.
Odor control biofilter for hydrogen sulfide and other odors at wastewater treatment plants, sewage collections systems, rest areas, landfills, composting, food industry, animal waste, chemical industry, industrial odor remover or industrial odor filter.
The wastewater odor control design and installation are simple since the biofilter design is done, just connect the power, foul air inlet, and water source.
Modular Biofilter Removal Rates
Modular odor control biofilter

1.8 to 20 cfm: Vent Biofilters are available in both a cartridge to fit inside an existing pipe or with a stainless steel housing. They are designed for H2S concentrations up to 100 ppm with at least a 99% removal rate. Simply slide the vent cartridge into the existing vent pipe. Maintenance only involves replacing the organic media in 5-7 years. Bioteg biofilters remove sewer gas odor from plumbing before anyone smells it; problem solved!
Odor control vent biofilter brochure
Vent cartridge biofilters Vent Biofilters Brochure |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

The Drop In biofilter can be hidden in a vault below or mostly below ground level to be inconspicuous and protected from vandalism. The odor control biofilter can be supported on the upper flange or base. The sewer gas flows in the bottom and is treated by the bacteria on the biofilter media, then exits the top odor free. The biofilter operating cost is low because the treatment is done by the bacteria which is self regenerating. Operating costs of carbon or chemical odor control systems are much higher because they are one time use media or chemical..
Pre-engineered
enclosed corrosion free biofilters for 12 cfm to 300 cfm
Up to seven
year media life
Compact Size
Easy to
install: set in place and connect water, power and air duct.
With or without blower
Commonly used for sewer lift stations, rest areas, industrial odors.
Odor Control Biofilters Drop In Flyer
Specially
designed to eliminate odors for lift stations or other odors. Prevent the odor complaints with no
additional maintenance.
·
Pre-engineered
enclosed systems for 15 cfm, 30 cfm and 45 cfm
Lift Station Biofilters can be quickly and easily installed above or below ground. Available with or with a blower. The HDPE and stainless steel construction is corrosion free.
Biofilters patented bio-media provides up to seven years of effective odor removal at >99% efficiency at 100 ppm.
Bioteg biofilters solve the problem of "How to get rid or sewer gas odor." Save money with biofilters to reduce odors since the overall cost is very low.
Please call for prices and application assistance:
Brian Moss
RJM Company
800-620-4774
Office: 360-828-5732
Cell: 360-903-0558
Fax: 208-988-6447
9808
NE 134th Ave, Vancouver,
WA 98682.
Common applications for odor control biofilters include: manhole odor control, industrial odor filter, wastewater odor control, odor control for lift station and pump stations, odor control biofilters